Reset storage array battery install date, Description, Syntax – Dell PowerVault MD3260i User Manual
Page 239: Parameter
Parameter
Description
•
errors—Statistics are reset for the most recent
20 failed resynchronization samples.
Notes
Statistics are reset for replicated virtual disks in the Primary role. The statistics that are reset include the following data:
•
Synchronization start time
•
Synchronization type (manual or periodic)
•
Synchronization duration
•
Number of bytes sent
•
Maximum and minimum write time (for a single write)
•
Maximum and minimum synchronization data rate
•
Total write time
•
Repository utilization (%)
•
Recovery point age
Reset Storage Array Battery Install Date
Description
This command resets the age of the batteries in a storage array to zero days. You can reset the batteries for an entire
storage array or just the battery for a specific RAID controller module or in a specific battery pack.
Syntax
reset storageArray batteryInstallDate controller=(0 | 1)
Parameter
Parameter
Description
controller
Specifies the RAID controller module that contains the
battery for which to reset the age. Valid RAID controller
module identifier values are 0 and 1. The identifier value
is 0 for the RAID controller module on the top and 1 for
the RAID controller module on the bottom when viewed
from the rear of the enclosure. Use the controller
parameter only for RAID controller modules with batteries.
NOTE: If you do not specify a RAID controller module, the age is reset for the storage array battery or both RAID
controller module batteries. If you specify a RAID controller module, then the age for only that RAID controller
module battery is reset.
239