Syntax Element Statement Data
Options for the Ethernet Port Parameter
enableIPv4=(TRUE | FALSE) |
enableIPv6=(TRUE | FALSE) |
IPv6LocalAddress=(0-FFFF):(0-FFFF):(0-FFFF):(0-
FFFF):(0-FFFF):(0-FFFF):(0-FFFF):(0-FFFF) |
IPv6RoutableAddress=(0-FFFF):(0-FFFF):(0-
FFFF):(0-FFFF):(0-FFFF):(0-FFFF):(0-FFFF):(0-
FFFF) |
IPv4Address=(0-255).(0-255).(0-255).(0-255) |
IPv4ConfigurationMethod=[(static | dhcp)] |
IPv4SubnetMask=(0-255).(0-255).(0-255).(0-255)|
duplexMode=(TRUE | FALSE) |
portSpeed=[(autoNegotiate | 10 | 100 | 1000)]
Options for the iscsiHostPort Parameter
IPv4Address=(0-255).(0-255).(0-255).(0-255) |
IPv6LocalAddress=(0-FFFF):(0-FFFF):(0-
FFFF):(0FFFF):(0-FFFF):(0-FFFF):(0-FFFF):(0-
FFFF) |
IPv6RoutableAddress=(0-FFFF):(0-
FFFF):(0FFFF):(0-FFFF):(0-FFFF):(0-FFFF):(0-
FFFF):(0-FFFF) |
IPv6RouterAddress=(0-FFFF):(0-FFFF):(0-
FFFF):(0-FFFF):(0-FFFF):(0-FFFF):(0-FFFF):(0-
FFFF) |
enableIPv4=(TRUE | FALSE) |
enableIPv6=(TRUE | FALSE) |
enableIPv4Vlan=(TRUE | FALSE) |
enableIPv6Vlan=(TRUE | FALSE) |
enableIPv4Priority=(TRUE | FALSE) |
enableIPv6Priority=(TRUE | FALSE) |
IPv4ConfigurationMethod=(static | dhcp) |
IPv6ConfigurationMethod=(static | auto) |
IPv4GatewayIP=(TRUE | FALSE) |
IPv6Priority=[0-7] |
IPv4SubnetMask=(0-255).(0-255).(0-255).(0-255)|
IPv4VlanId=[1-4094] |
IPv6VlanId=[1-4094] |
maxFramePayload=[frameSize] |
tcpListeningPort=[3260, 49152-65536] |
portSpeed=[(autoNegotiate | 1 | 10)]
Additional Information
When you use this command, you can specify one or more of the parameters. You do not need to use all of the
parameters. Setting the availability parameter to serviceMode causes the alternate RAID controller module to
take ownership of all of the virtual disks. The specified RAID controller module no longer has any virtual disks and
refuses to take ownership of any more virtual disks. Service mode is persistent across reset cycles and power cycles
until the availability parameter is set to online.