Parameters

Parameter

Description

physicalDiskType

Type of physical disk to use for the storage array. Valid

physical disk type is SAS. This parameter is not required if

only one type of physical disk is in the storage array.

raidLevel

RAID level of the disk group that contains the physical

disks in the storage array. Valid RAID levels are 0, 1, 5

or 6.

diskGroupWidth

Number of physical disks in a disk group in the storage

array. This number depends on the capacity of the

physical disks. Integer values are required. For

information about the number of physical disks that you

can use in a disk group, see Enclosure Loss Protection.

diskGroupCount

Number of disk groups in the storage array. Use integer

values.

virtualDisksPerGroupCount

Number of equal-capacity virtual disks per disk group. Use

integer values.

hotSpareCount

Number of hot spares desired in the storage array. Use

integer values. For information about hot spares, see

Assigning Global Hot Spares.

segmentSize

Amount of data (in kilobytes) that the RAID controller

module writes on a single physical disk in a virtual disk

before writing data on the next physical disk. Valid values

are 8, 16, 32, 64, 128, 256, or 512. For information

about the segmentSize parameter, see Using The Auto

Configure Command.

cacheReadPrefetch

The setting to turn on or turn off cache read prefetch. To

turn off cache read prefetch, set this parameter to
FALSE. To turn on cache read prefetch, set this

parameter to TRUE.

securityType

The setting to specify the security level when creating the

disk groups and all associated virtual disks. These settings

are valid:

none—The disk group and virtual disks are not

secure.

capable—The disk group and virtual disks are

capable of having security set, but security has

not been enabled.

enabled—The disk group and virtual disks have

security enabled.

Show Storage Array Core Dump

Description

This command show details of the core dump on the RAID controller module cache, if a core dump is available.

337