Autoconfigure storage array hot spares, Blink ssd cache – Dell PowerVault MD3260i User Manual
Page 138
Parameter
Description
securityType
The setting to specify the security level when creating the
disk groups and all associated virtual disks.
•
none—The disk group and virtual disks are not
secure.
•
capable—The disk group and virtual disks are
capable of having security set, but security has
not been enabled.
•
enabled—The disk group and virtual disks have
security enabled.
Autoconfigure Storage Array Hot Spares
Description
This command automatically defines and configures the hot spares in a storage array. You can run this command at any
time. This command provides the best hot spare coverage for a storage array.
Syntax
autoConfigure storageArray hotSpares
Parameters
None.
NOTE: When you run the autoconfigure storageArray hotSpares command, the RAID controller
module firmware determines the number of hot spares to create based on the total number and type of physical
disks in the storage array.
Blink SSD Cache
Description
The start locate command identifies the Solid State Disks (SSDs) that are being used in the SSD cache by turning
on the indicator lights for the SSDs. The stop locate command turns off the indicator lights on the SSDs.
Syntax Applicable To Starting A Blink Operation
start ssdCache [ssdCacheName] locate
Syntax Applicable To Stopping A Blink Operation
stop ssdCache locate
138