beautypg.com

Autoconfigure storage array hot spares, Blink ssd cache – Dell PowerVault MD3260i User Manual

Page 138

background image

Parameter

Description

securityType

The setting to specify the security level when creating the
disk groups and all associated virtual disks.

none—The disk group and virtual disks are not

secure.

capable—The disk group and virtual disks are

capable of having security set, but security has

not been enabled.

enabled—The disk group and virtual disks have

security enabled.

Autoconfigure Storage Array Hot Spares

Description

This command automatically defines and configures the hot spares in a storage array. You can run this command at any
time. This command provides the best hot spare coverage for a storage array.

Syntax

autoConfigure storageArray hotSpares

Parameters

None.

NOTE: When you run the autoconfigure storageArray hotSpares command, the RAID controller
module firmware determines the number of hot spares to create based on the total number and type of physical
disks in the storage array.

Blink SSD Cache

Description

The start locate command identifies the Solid State Disks (SSDs) that are being used in the SSD cache by turning
on the indicator lights for the SSDs. The stop locate command turns off the indicator lights on the SSDs.

Syntax Applicable To Starting A Blink Operation

start ssdCache [ssdCacheName] locate

Syntax Applicable To Stopping A Blink Operation

stop ssdCache locate

138