DC Analog Tachometer Terminal Block
Figure 62 - Analog Tachometer Terminal Block Location
See the PowerFlex Digital DC Drive Technical Data, publication
,
for DC analog tachometer specifications.
Table 39 - DC Analog Tachometer Terminal Designations
Resolver Feedback Module
The resolver feedback module (catalog number 20P-RES-A0), which provides a
drive interface to a selection of compatible resolvers, must be ordered and
purchased separately from the drive. The resolver option module includes the
PowerFlex DC Drive Resolver Feedback Module Installation Instructions,
publicatio
Resolver Type Selection on page
for more information on compatible
resolvers.
ATTENTION: The drive can overspeed if DIP switch S4 is set incorrectly, or the
tachometer is wired incorrectly. Failure to observe this precaution could result in
damage to, or destruction of, the equipment.
Label Signal
Description
–
Negative input
–
A
(Not Used)
B
C
+
Positive input
See Verify Motor Rotation and Run Feedback
Polarity Checks on page
for information
on determining feedback polarity.
22.7 / 45.4 / 90.7 / 181.6 / 302.9V
(1)
max voltage
8 mA max. current
(1) Maximum voltage depends on the configuration of DIP switch S4. See DC Analog Tachometer DIP Switch S4 Example on page
77
.
Analog Tachometer
terminal block
A
B
C
+
−