Rockwell Automation 23P PowerFlex Digital DC Drive User Manual
Page 168
168
Rockwell Automation Publication 20P-UM001K-EN-P - July 2014
Chapter 3
Programming and Parameters
APPLIC
AT
IONS
Win
der
Fu
nc
ti
on
s
1284 [Ref Spd Source]
Parameter number from which the line speed reference (used for inertia
compensation and line speed reference) will be read.
Notes: Added options 0…47 for firmware version 4.001. Added option 48
“Resolver Spd” for firmware version 5.002.
Default:
0 =
“Not Used”
16-bit
Int
Options:
1285 [Ref Speed Gain]
Gain value for the line speed reference. The value of this parameter depends on the
value of Par 1284 [Ref Spd Source]. The value of [Ref Speed Gain] is used to obtain
a line speed reference = 100% at its maximum value.
Default:
Min/Max:
0
0 / 32767
16-bit
Int
1284
1286 [Ref Line Speed]
Line speed percentage.
Default:
Min/Max:
Units:
Read Only
0.00 / 150.00
%
Real
1287 [Static F Zero]
Enables/Disables friction compensation.
• “Enabled” = The fiction compensation value is added to all speed values.
• “Disabled” = The static friction compensation value is added to Par 1286 [Ref
Line Speed] = 1.5%.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
16-bit
Int
1286
Fil
e
Gr
oup
No
.
Parameter Name & Description
See
page 114
for symbol descriptions
Values
Da
ta
T
yp
e
Rela
ted
A
0 =
“Not Used”
17 = “Max Fld Pct” (Par 467)
34 = “UsrDefined15” (Par 518)
1 =
“Cur Lim Pos” (Par 8)
18 = “Fld Ref Pct” (Par 500)
35 = “Load Comp” (Par 698)
2 =
“Cur Lim Neg” (Par 9)
19 = “UsrDefined0” (Par 503)
36 = “Out Volt Lvl” (Par 921)
3 =
“CurLimPosOut” (Par 10)
20 = “UsrDefined1” (Par 504)
37 = “Filt Trq Cur” (Par 928)
4 =
“CurLimNegOut” (Par 11)
21 = “UsrDefined2” (Par 505)
38 = “Speed Ratio” (Par 1017)
5 =
“TrqRedCurLim” (Par 13)
22 = “UsrDefined3” (Par 506)
39 = “Spd Draw Out” (Par 1018)
6 =
“Torque Ref” (Par 39)
23 = “UsrDefined4” (Par 507)
40 = “Roll Diam” (Par 1154)
7 =
“Trim Torque” (Par 40)
24 = “UsrDefined5” (Par 508)
41 = “Tension Red” (Par 1179)
8 =
“TorqueReg In” (Par 41)
25 = “UsrDefined6” (Par 509)
42 = “Torq Cur Pct” (Par 1193)
9 =
“Trim Ramp” (Par 42)
26 = “UsrDefined7” (Par 510)
43 = “Ten Ref Pct” (Par 1194)
10 = “Trim Speed” (Par 43)
27 = “UsrDefined8” (Par 511)
44 = “CloseLp Comp” (Par 1208)
11 = “Ramp In” (Par 110)
28 = “UsrDefined9” (Par 512)
45 = “Actual Comp” (Par 1213)
12 = “Ramp Out” (Par 113)
29 = “UsrDefined10” (Par 513)
46 = “W Reference” (Par 1217)
13 = “Speed Reg In” (Par 118)
30 = “UsrDefined11” (Par 514)
47 = “Encoder Spd” (Par 420)
14 = “Adaptive Ref” (Par 183)
31 = “UsrDefined12” (Par 515)
48 = “Resolver Spd” (Par 428)
15 = “Arm Cur Pct” (Par 199)
32 = “UsrDefined13” (Par 516)
16 = “SpdRegOutPct” (Par 236)
33 = “UsrDefined14” (Par 517)
A
A
A