Using the s.m.a.r.t. list screen, E using the s.m.a.r.t. list screen on – Rockwell Automation 23P PowerFlex Digital DC Drive User Manual
Page 267

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014
267
HIM Overview
Appendix B
Using the S.M.A.R.T. List Screen
The LCD HIM provides the S.M.A.R.T. list screen which contains some of the
most commonly changed parameters, including the following:
Some important Start Up parameters are not included in this screen. Refer to
Drive Start Up on page
for detailed instructions.
Parameter Name / Number
Description
[Max Ref Speed] (45)
The nameplate base motor speed.
[Rated Motor Volt] (175)
The maximum armature voltage of the drive output.
[Nom Mtr Arm Amps] (179)
Corresponds to 100% of the current limit.
[Nom Mtr Fld Amps] (280)
Rated motor nameplate field current.
[Anlg In1 Sel] (70)
Selects the parameter to which a value will be written from analog input 1
(default = “Speed Ref A”)
[Maximum Speed] (2)
Defines the maximum speed of the drive.
[Current Limit] (7)
Symmetrical current limit for both current directions for four quadrant drives,
expressed as a percentage of the value in parameter 179 [Nom Mtr Arm Amps].
[Accel Time 1] (660)
Sets the rate of acceleration for Ramp 0.
[Fdbk Device Type] (414)
The source of speed feedback.