Supplemental Drive Information
Dynamic Brake Resistor Kits
and DC Output Contactors
See
for recommended alternate DC Output
Contactors for 575V and 690V AC input drives, respectively.
Table 80 - 230V AC Input Drives
Table 81 - 460V AC Input Drives
Fram
e
Drive Current
Rating Code
DC
Amps
AC Line
Amps
Hp
Dynamic Brake
Resistor Kit Cat. No.
Armature
Voltage
(Volts)
Total DB
Resistance
(ohms)
DC Loop Contactor Cat. No.
(2)
DC Contactor
Crimp Lugs
Cat. No.
(3)
Drive without Dynamic
Brake
Drive with Dynamic
Brake
A 7P0
7
5.7
1.5
1370-DBL62
240
20
1370-NC56
1370-DC56
1370-LG40
9P0
9
7.4
2
1370-DBL63
240
20
1370-NC56
1370-DC56
1370-LG40
012
12
9.8
3
1370-DBL64
240
15
1370-NC56
1370-DC56
1370-LG40
020
20
16
5
1370-DBL65
240
8.6
1370-NC56
1370-DC56
1370-LG40
029
29
24
7.5
1370-DBL66
240
6
1370-NC56
1370-DC56
1370-LG40
038
38
31
10
1370-DBL67
240
5
1370-NC56
1370-DC56
1370-LG40
055
55
45
15
1370-DBL68
240
3.5
1370-NC56
1370-DC56
1370-LG56
073
73
60
20
1370-DBL69
240
2.6
1370-NC110
1370-DC110
1370-LG92
093
93
76
25
1370-DBL70
240
2
1370-NC110
1370-DC110
1370-LG92
110
110
90
30
1370-DBL71
240
2
1370-NC110
1370-DC110
1370-LG110
B
146
146
119
40
1370-DBL72
240
1.4
1370-NC180
1370-DC180
1370-LG160
180
180
147
50
1370-DBL73
240
1.0
1370-NC180
1370-DC180
1370-LG180
218
218
178
60
1370-DBL74
240
1.0
1370-NC280
1370-DC280
1370-LG228
265
265
217
75
1370-DBL75
240
0.67
1370-NC280
1370-DC280
1370-LG268
360
360
294
100
1370-DBL76
240
0.47
ABB_EHDB360C2P-1L2S
ABB_EHDB360C-1L22SS
(4)
434
434
355
125
CUTLER-
HAMMER_G3AP50
(Qty 4 - two in series,
two in parallel)
240
0.4
ABB_EHDB520C2P-1L2S
ABB_EHDB520C-1L22SS
(4)
C
521
521
426
150
HUBBELL_Y139W322
GB
240
0.322
(4)
700
700
572
200
(1)
240
0.25
ABB_EHDB800C2P-1L2S
ABB_EHDB800C-1L22SS
(4)
D 875
875
715
250
(1)
240
0.2
ABB_EHDB960C2P-1L2S
ABB_EHDB960C-1L22SS
(4)
1K0
1050
858
300
(1)
240
0.2
SIEMENS-MFG_14-193-
101-58-2 (Qty 2)
SIEMENS-MFG_14-193-
101-58-2 (Qty 1)
(4)
(1) No Dynamic Brake Resistor kit available for this drive rating - must be sourced locally.
(2) Coil voltage = 115V AC, 50/60Hz.
(3) See DC Contactor Crimp Lug Kit Specifications on page
for more information.
(4) Wire and Lug size dependant on enclosure dimensions and local codes.
Fram
e
Drive Current
Rating Code
DC
Amps
AC Line
Amps
Hp
Dynamic Brake Resistor
Kit Cat. No.
Armature
Voltage
(Volts)
Total DB
Resistance
(ohms)
DC Loop Contactor Cat. No.
(2)
DC Contactor
Crimp Lugs
Cat. No.
(3)
Drive without Dynamic
Brake
Drive with Dynamic
Brake
A 4P1
4.1
3.3
2
1370-DBH63
500
81
1370-NC56
1370-DC56
1370-LG40
6P0
6
4.9
3
1370-DBH64
500
62
1370-NC56
1370-DC56
1370-LG40
010
10
8.2
5
1370-DBH65
500
45
1370-NC56
1370-DC56
1370-LG40
014
14
11.4
7.5
1370-DBH66
500
27
1370-NC56
1370-DC56
1370-LG40
019
19
15.5
10
1370-DBH67
500
20
1370-NC56
1370-DC56
1370-LG40
027
27
22.1
15
1370-DBH68
500
12
1370-NC56
1370-DC56
1370-LG40
035
35
28.6
20
1370-DBH69
500
10
1370-NC56
1370-DC56
1370-LG40
045
45
36.8
25
1370-DBH70
500
9
1370-NC56
1370-DC56
1370-LG52
052
52
42.5
30
1370-DBH71
500
7
1370-NC56
1370-DC56
1370-LG52
073
73
59.6
40
1370-DBH72
500
5.2
1370-NC110
1370-DC110
1370-LG92
086
86
70.3
50
1370-DBH73
500
4
1370-NC110
1370-DC110
1370-LG92
100
100
81.7
60
1370-DBH74
500
4
1370-NC110
1370-DC110
1370-LG110
129
129
105.4
75
1370-DBH75
500
3
1370-NC180
1370-DC180
1370-LG140
B 167
167
136.4
100
1370-DBH76
500
2.1
1370-NC180
1370-DC180
1370-LG180
207
207
169.1
125
1370-DBH77
500
2.1
1370-NC280
1370-DC280
1370-LG228
250
250
204.3
150
1370-DBH78
500
1.5
1370-NC280
1370-DC280
1370-LG268
330
330
269.6
200
1370-DBH79
500
1.05
ABB_EHDB360C2P-1L2S
ABB_EHDB360C-1L22SS
(4)
412
412
336.6
250
HUBBELL_Y95W808GB
500
1
ABB_EHDB520C2P-1L2S
ABB_EHDB520C-1L22SS