Speed up function, For mo, E speed up function – Rockwell Automation 23P PowerFlex Digital DC Drive User Manual
Page 320: Speed up function o
320
Rockwell Automation Publication 20P-UM001K-EN-P - July 2014
Appendix C
Application Notes
Speed Up Function
The Speed-up function is used to avoid oscillations in the presence of loads with a
high moment of inertia. When this function is enabled (default value of 0 “Speed
Up” in Par 1016 [SpdFuncSelect]), a D (derivative) value is added to the speed
feedback circuit, which allows you to increase the integral gain of the speed
regulator. It is also useful in the case of cyclical non-constant loads on the motor
(for example, cams). The feedback applied to the speed regulator is made of two
components:
•
the motor speed
•
the output signal from the Speed Up function
Parameters used in the example:
•
Par 445 [Spd Up Gain Pct] = 50%
•
Par 446 [Speed Up Base] = 14 rpm/ms
•
Par 447 [Speed Up Filter] = 20 ms
Figure 88 - Speed-Up function inactive
Oscillation during a speed change due to a high moment of inertia.
Top: Par 122 [Spd Feedback]
Bottom: Par 199 [Arm Current Pct]
Figure 89 - Speed-up function active
The same drive with Speed-up function active.
Top: Par 122 [Spd Feedback]
Bottom: Par 199 [Arm Current Pct]