1113 [ZeroSpdFloatTime]
Amount of time the drive is at or below the speed set in Par 1111 [Float Tolerance]
before the brake is set. This parameter is not used when Par 1100 [Torq Prove Cfg]
Bit 1 “Encoderless” is set to “1” (enabled).
Note: This parameter was added for firmware version 6.001.
Default:
Min/Max:
Units:
5.0
0.1 / 500.0
s
Real
1100
1114 [Brake Test Torq]
Percent of torque applied to the motor before the brake is released when Par 1100
[Torq Prove Cfg], bit 7 “Test Brake” is set to “1” (enabled).
Note: This parameter was added for firmware version 6.001.
Default:
Min/Max:
Units:
50
0 / 150
%
Real
1100
Sca
le
B
lo
ck
s
484
553
1218
1227
1236
1245
[Scale1 Input]
[Scale2 Input]
[Scale3 Input]
[Scale4 Input]
[Scale5 Input]
[Scale6 Input]
Parameter number from which the value is read and used as the input quantity to
the Scale block. See the Scale Blocks block diagram on page
for more
information.
Default:
Min/Max:
0
0 / 1410
16-bit
Int
485
554
1219
1228
1237
1246
[Scale1 Output]
[Scale2 Output]
[Scale3 Output]
[Scale4 Output]
[Scale5 Output]
[Scale6 Output]
Parameter number to which the value of the Scale block output is written. See the
Scale Blocks block diagram on page
for more information.
Default:
Min/Max:
0
0 / 1410
16-bit
Int
486
555
1220
1229
1238
1247
[Scale1 Mul]
[Scale2 Mul]
[Scale3 Mul]
[Scale4 Mul]
[Scale5 Mul]
[Scale6 Mul]
Multiplier of the input quantity (after a possible limitation). Resolution:
5 digits. See the Scale Blocks block diagram on page
for more information.
Default:
Min/Max:
1.00
–/+10000.00
Real
487
556
1221
1230
1239
1248
[Scale1 Div]
[Scale2 Div]
[Scale3 Div]
[Scale4 Div]
[Scale5 Div]
[Scale6 Div]
Divisor, through which it is possible to divide the input quantity already multiplied
and limited. Resolution: 5 digits. See the Scale Blocks block diagram on page
for more information.
Default:
Min/Max:
1.00
–/+10000.00
Real
488
557
1222
1231
1240
1249
[Scale1 In Max]
[Scale2 In Max]
[Scale3 In Max]
[Scale4 In Max]
[Scale5 In Max]
[Scale6 In Max]
Maximum limit of the input quantity. Resolution: 5 digits. See the Scale Blocks
block diagram on page
for more information.
Default:
Min/Max:
0.00
– 2
31
/ +2
31
– 1
Real
489
558
1223
1232
1241
1250
[Scale1 In Min]
[Scale2 In Min]
[Scale3 In Min]
[Scale4 In Min]
[Scale5 In Min]
[Scale6 In Min]
Minimum limit of the input quantity. Resolution: 5 digits. See the Scale Blocks
block diagram on page
for more information.
Default:
Min/Max:
0.00
– 2
31
/ +2
31
– 1