Utility file, Param access lvl – Rockwell Automation 23P PowerFlex Digital DC Drive User Manual
Page 173

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014
173
Programming and Parameters
Chapter 3
Utility File
Fil
e
Gr
oup
No
.
Parameter Name & Description
for symbol descriptions
Values
Da
ta
T
yp
e
Rela
ted
UTILIT
Y
R
ef
ere
nce C
onf
ig
209
[Save HIM Ref]
Enables a feature to save the present reference value issued by the HIM to drive memory when a power loss occurs. The value is restored to the HIM at power
up.
Bit 0 - “At Pwr Down” 0 = Do not save, 1 = Save at power down
210
[Man Ref Preload]
Enables/disables a feature to automatically load the present “Auto” reference
value into the HIM when “Manual” is selected. Allows smooth speed transition
from “Auto” to “Manual.”
Default:
Options:
1 =
0 =
1 =
“Enabled”
“Disabled”
“Enabled”
16-bit
Int
249
[MOP Ref Config]
Enables/Disables the feature that saves the present MOP reference at power down or at stop.
Notes: This parameter can be assigned to a digital input. Bits 2 and 3 were added for firmware version 6.001.
• Bit 0 “Save PwrDown” - When set to “0” = Do not save, “1” = Save
• Bit 1 “Save At Stop” - When set to “0” = Do not save, “1” = Save
• Bit 2 “Reset AtStop” - When set to “0” = No MOP reset, “1” = Reset MOP at Stop
• Bit 3 “Reset At Flt” - When set to “0” = No MOP reset, “1” = Reset MOP at Fault
1322 [Direction Mode]
Selects the method that will be used for changing direction.
• “Unipolar” - Drive Logic determines the direction.
• “Bipolar” - The sign of the reference determines the direction.
• “Rev Disable” - Forward direction only (not changeable).
Default:
Options:
0 =
0 =
1 =
2 =
“Unipolar”
“Unipolar”
“Bipolar”
“Rev Disable”
16-bit
Int
1375 [MOP Select]
Selects the destination of the MOP signal.
Default:
Options:
0 =
0 =
1 =
2 =
3 =
4 =
“OFF”
”OFF”
“Speed Ref A”
“Speed Ref B”
“Trim Speed”
“TB Man Ref”
16-bit
Int
Dr
iv
e M
em
or
y
211
[Param Access Lvl]
Selects the parameter display level.
• “Basic” = Reduced parameter set.
• “Advanced” = Full parameter set.
Default:
Options:
0 =
0 =
1 =
“Basic”
“Basic”
“Advanced”
16-bit
Int
258
[Reset Defaults]
Setting this parameter to 1 “Factory” will load the default settings in the drive
firmware.
Default:
Options:
0 =
0 =
1 =
“Ready”
“Ready”
“Factory”
16-bit
Int
302
[Language]
Selects the operating language of the drive. Only two languages are available in
the drive at any given time, English and one of the following: French, German,
Italian, Portuguese, or Spanish. The drive ships with the default language options
of English and Spanish only. The additional language files can be downloaded at:
Note: This parameter was added for firmware version 3.001.
Default:
Options:
0 =
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
“Not Selected”
“Not Selected”
“English”
“French”
“Spanish”
“Italian”
“German”
“Reserved”
“Portuguese”
16-bit
Int
Options
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
At
P
w
r D
ow
n
Default
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Options
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
ser
ve
d
Re
set A
t F
lt
Re
set A
tS
top
Sa
ve
A
t S
to
p
Sa
ve
Pwr
D
ow
n
Default
x
x
x
x
x
x
x
x
x
x
x
x
0
0
0
0
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1