2 initial state of the state transitions, Initial state of the state transitions, Architecture: the applicationtemplate in detail – Lenze PLC Designer ApplicationTemplate (PLC Designer R3-x) User Manual
Page 78
Architecture: The ApplicationTemplate in detail
State machine
78
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Special "Warning" status
"Warning" is a special status (independent, "orthogonal" state), which does not influence the
operational performance of the machine module.
• Possible states:
...active: "Warning" (or: ...not active: "No Warning")
9.3.2
Initial state of the state transitions
The state transitions between the module state machine and the module applications are in the
initial state as follows:
By means of methods, the state transitions can be influenced (enable/inhibit).
...
User-defined
Mode 1...2
User-definable states
• ... depend on the application of the respective machine
Homing
In the "Homing" state, the drive is referenced. Either the home
position is set directly, or a homing process is started.
...
Upcoming
error states
May occur at any time.
• A machine module, machine modules of the same hierarchy level,
or subordinated slaves can cause errors.
• The module application cannot inhibit the state transitions when
the error status occurs.
• By programming the machine modules, the response to an error
status can be defined.
...
Error
"Error" status
,
Ready for operation
Ready
"Ready for operation" status
• When the error has been eliminated/acknowledged successfully
Quick stop
"Quick stop" status
• A requirement to acknowledge errors can be parameterised.
Error
Fault
"System fault" status
• For completion, the PLC must be reset.
System fault
Systemfault
"Error" status
• Requires acknowledgement.
Labelled with
State/identifier
Description
State transition
Description
2-13
Are enabled in the initial state (after RESET)