The L_EATP_ApplicationTemplate library

1_POUs - Program Organization Units

122

Lenze · ApplicationTemplate · 1.3 EN - 04/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.2.6

RegisterACD()

This method records the ACD structure in the module FB (MFB).

11.2.7

setCompIDAndVersion()

This method sets the module ID (CompID) and version of the machine module.

Inputs

RegisterACD

L_EATP_ACD_Base

⎯ scStruct

DWORD ⎯ dwSize

Identifier/data type

Information/possible settings

scStruct

L_EATP_ACD_Base

Transferred structure is to be derived from the L_EATP_ACD_Base structure. (e.g.:

TYPE MACD_scExample EXTENDS L_EATP_ACD_Base)

dwSize

DWORD

Size of the structure transferred (e.g.: SIZEOF(MACD_scExample) )

Identifier/data type

Information/possible settings

dwCompID

DWORD

Module ID

• The free area of the CompID is between 16#3C00 – 16#3FF

dwVersion

DWORD

Version of the machine module