The L_EATP_ApplicationTemplate library
3_Enums
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.3.5
L_EATP_MM_Address
This structure defines the module address (data type: INT).
11.3.6
L_EATP_MVis
The structure contains data for the external visualization with the Lenze Engineering
tool »VisiWinNET« (optional).
11.3.7
L_EATP_scBase
The structure contains the module name (data type: STRING).
11.4
3_Enums
11.4.1
L_EATP_ErrorReactionType
This enumeration contains the error response types. The numerical constants are sorted according
to the valency and meaning in ascending order.
sText
STRING
Error text (English)
dwErrDetail
DWORD
Detailed error information
xAckNeeded
BOOL
Note:
Is ignored for the following error response types:
• "Information": Acknowledgement not required
• "Fault": Error. Acknowledgement is always required
• "SystemFault": System error. No acknowledgement possible
FALSE Error acknowledgement not required.
TRUE Error acknowledgement required.
Identifier/data type
Information/possible settings
Identifier
Numerical
constant
Response type
None
0
No response/not used
Information
1
Information
Warning
2
Warning
Quick stop
3
Quick stop (QSP)
Fault
4
Error
SystemFault
5
System fault