Opening the ApplicationTemplate
Update the controller in the project (optional)
32
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.2
Update the controller in the project (optional)
Cases in which the project must be updated
The controller in the »PLC Designer« must be updated if ...
• ...the project contains firmware information that is older than the hardware to be used or
• ...a controller other than the integrated 3200 C controller is desired (example: p500).
If the controller is marked with the
icon after the project is opened, the device information of
the »PLC Designer« project have to be updated.
Determining the firmware of the controller
How to proceed:
• Use the »WebConfig« to check which firmware is used by the controller to select the
appropriate device information in the »PLC Designer«.
• If the controller must be updated, the dynamic memory settings of the application must be
adapted.
Adapting the memory settings
Highlight the desired controller.
• Execute the Update device command in the context menu.
• Double-click the applicable controller in the Update device dialog window to update the
controller in the Device view:
1. In the context menu of
Application, execute the
Properties command.
• On the Application build options tab, activate the; Use dynamic memory allocation
option.
• For Maximum size of memory, enter a value of 100000:
• Click OK to confirm.