9 l_eatp_moduleerrorhandler, L_eatp_moduleerrorhandler, L_eatp_moduleerrorhandler ( 124) – Lenze PLC Designer ApplicationTemplate (PLC Designer R3-x) User Manual
Page 124: The l_eatp_applicationtemplate library
The L_EATP_ApplicationTemplate library
1_POUs - Program Organization Units
124
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.2.9
L_EATP_ModuleErrorHandler
This FB contains the central error handling in a machine module.
• An instance of this block called ErrorHandler is part of the basic block L_EATP_Module.
Input
Output
L_EATP_ModuleErrorHandler
BOOL ⎯ xQuitErrors
xErrorQuitActive ⎯ BOOL
Identifier/data type
Information/possible settings
xQuitErrors
BOOL
Set the input to TRUE to activate the acknowledgement of errors (edge
FALSEÊTRUE). The module application (MAP) is the error source.
Identifier/data type
Information/possible settings
xQuitErrorActive
BOOL
TRUE Shows whether the acknowledgement of errors is active. Is active...
• ... as long as xQuitErrors = TRUE or
• for one cycle if the acknowledgement of errors is activated by
means of the baseChannelSetErrorQuit method.
Method overview - ApplicationTemplate ( 131)
FALSE The acknowledgement of errors is deactivated, xQuitErrors = FALSE.