3 loadfromandwriterecipe, Loadfromandwriterecipe, Appendix – Lenze PLC Designer ApplicationTemplate (PLC Designer R3-x) User Manual
Page 148

Appendix
Recipe manager
148
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.4.5.3
LoadFromAndWriteRecipe
...loads the recipe from the file specified to "_stRecipe2" and
...writes the recipe to the current PLC values
[12-10] Example: Program view
Initial situation:
Result:
The values of the "Recipe_2011_10_01.txtrecipe" recipe (file) have been...
VAR
_RecipeManCommands : RecipeManCommands;
_stRecipeDef : STRING := 'MM_Par_Modul1';
[name of the recipe
definition]
_stRecipe1: STRING := 'Recipe1';
_stRecipe2: STRING := 'Recipe2';
_stRecipe3: STRING := 'Recipe3';
_stFileName1: STRING := 'Recipe2011_11_01.txtrecipe';
_stFileName3: STRING := 'Recipe3. MM_Par_Modul1.txtrecipe';
END_VAR
MM_Par.Par_Printer.lrPar1:=325.68;
MM_Par.Par_Printer.wPar4:= 375;
_RecipeManCommands.LoadFromAndWriteRecipe(_stRecipeDef,_stRecipe2,_stFileName1);
• The values (to be transferred) of the
"Recipe_2011_10_01.txtrecipe" recipe
definition.
• ...transferred to the current PLC values
(column
).
• ...transferred to the
"Recipe3.MM_Par_Modul1.txtrecipe"
recipe (file).