Architecture: the applicationtemplate in detail – Lenze PLC Designer ApplicationTemplate (PLC Designer R3-x) User Manual
Page 103
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
103
Architecture: The ApplicationTemplate in detail
Internal Control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[9-30] Instance of the "Module1" machine module in the variable view
If "Internal Control" is active, ...
• ...a write operation by the master has no effect on the module. The write operation of the
module's intrinsic application (MAP) will prevail instead.
• ...a read operation by the master or the module's intrinsic MAP supplies the current machine
module values.
If "Internal Control" is deactivated, ...
• ...a write operation by the master to the module can be executed.
• ...a write operation of the module's intrinsic MAP will prevail.
• ...a read operation by the master or the module's intrinsic MAP supplies the current machine
module values.
• The following is highlighted:
• The switches (TRUE/FALSE) for
activating the "Internal Control"
(xInternalControl)
• The references to the module's
intrinsic baseChannel (blue marking)