11 l_eatp_smaccess, L_eatp_smaccess, L_eatp_smaccess ( 126) – Lenze PLC Designer ApplicationTemplate (PLC Designer R3-x) User Manual
Page 126: The l_eatp_applicationtemplate library
The L_EATP_ApplicationTemplate library
1_POUs - Program Organization Units
126
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.2.11
L_EATP_SMAccess
This FB shows the current state of the state machine in a module application (MAP).
• The SMAccess instance of this FB...
• ...is integrated into the ApplicationTemplate project in each module application.
• ...is represented graphically in the Statemachine FUP method.
Outputs
At the outputs, the FB provides the information on the current status of the state machine to the
module application.
Function library:
L_EATP_ApplicationTemplate
Runtime software licence:
LPC 1x00
MPC 1x00
MPC 2x00
MPC 2x10
MPC 2x20
MPC 2x30
MPC 3x00
;
None
SMAccess
L_EATP_SMAccess
eNomState ⎯
eActState ⎯
xWarning ⎯
xActStateIsInit ⎯
xActStateIsReady ⎯
xActStateIsManual ⎯
xActStateIsService ⎯
xActStateIsMode[1...2] ⎯
xActStateIsHoming ⎯
xActStateIsQuickStop ⎯
xActStateIsFault ⎯
xActStateIsSystemFault ⎯
Transfer variables
Identifier/data type
Value/meaning
eNomState
Required TARGET status of the state machine
eActState
Current ACTUAL status of the state machine
xWarning
BOOL
Warning is active
xActStateIsInit
BOOL
TRUE Current ACTUAL status: "Init"
xActStateIsReady
BOOL
TRUE Current ACTUAL status: "Ready"
xActStateIsManual
BOOL
TRUE Current ACTUAL status: "Manual"
xActStateIsService
BOOL
TRUE Current ACTUAL status: "Service"