Opening the applicationtemplate – Lenze PLC Designer ApplicationTemplate (PLC Designer R3-x) User Manual
Page 38
Opening the ApplicationTemplate
Visualisation of the machine modules
38
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
• Depending on the standard response,
triggering an error at L_EATP_ErrorSet
results in a state change in area
.
• Possible error responses are: Error,
SystemFault, Warning, Information.
• Default setting of the
ApplicationTemplate (can be deactivated,
if required):
When an error is triggered, the higher-level
machine module changes to the "Quick
stop" state.
• The machine module forwards the state
to the higher-level machine module.
• The machine module on the top level
sets all lower-level machine modules to
the "Quick stop" status.
• The Module List button calls the detailed
view for the machine modules.
• Click the desired machine module to show
the respective status and further details.
• The Error List button calls the global error
list which provides an overview of the
errors that have occurred.
• The cause of the fault activation must
be eliminated. Then the corresponding
error must be reset.
• To reset the error, the Error Quit button
is to be pressed.