SkyTrak 6036 Service Manual User Manual
Page 288

Hydraulic System
8.72
Model 6036 Legacy
9. Wipe up any hydraulic fluid spillage in, on, near and
around the vehicle and the work area.
10. Remove the three hex flange nuts (Fig. 8-39, 1) and
carriage bolts (2 and 3) securing the main control
valve (4) to the frame (5).
11. Remove the main control valve (Fig. 8 -39, 4) from
the frame.
Figure 8-39 Main Control Valve Removal
MA7280
5
2
1
1
3
4
Front