Protection facility specification, Protection facility specification 82 – HP XP RAID Manager Software User Manual
Page 82

82
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
Protection facility specification
Only permitted volumes and volumes visible to the host can be listed in the
horcm.conf file. A volume must fulfill two requirements to be considered
“permitted” by the RM protection facility:
• It is host viewable (for example, with the HP supplied Inquiry tool).
• It is a volume listed in the horcm.conf file.
RM manages volume mirror descriptors (MU# for CA, BC0/BC1/BC2) as
a unit. The permitted volumes in the following table lie at the intersection
(the dark shaded areas) of volume device files, representing volumes that
the host is allowed to see (row), and volumes that are listed in the
horcm.conf file (column).
Guide to table terms:
L
The volume mirror descriptor is listed in the
horcm.conf file.
Not
The volume mirror descriptor is not listed in the
horcm.conf file.
Unknown
Volumes that the host cannot see, even though the
volumes were listed in the horcm.conf file.
P
Permitted
N
Not permitted
Volumes on
horcm.conf
Mirror descriptor defined in horcm.conf
CA
BC0
BC1
BC2
L
not
L
not
L
not
L
not
Unknown
N
N
N
N
N
N
N
N
/dev/rdsk/c0t0d0
P
N
P
N
P
N
P
N
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)