HP XP RAID Manager Software User Manual
Page 252
252
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
Example
raidvchkdsp -g vg01 -v pool
Group PairVol Port# TID LU Seq# LDEV# Bsize Available Capacity
Vg01 oradb1 CL2-D 2 7 62500 167 2048 100000 1000000000
Vg01 oradb2 CL2-D 2 10 62500 170 2048 100000 1000000000
Bsize
: This displays the data block size of the pool, in
units of block(512bytes).
Available(Bsize)
: This displays the available capacity
for the volume data on the SnapShot pool in units of
Bsize.
Capacity(Bsize)
: This displays the total capacity in the
SnapShot pool in units of Bsize.
[Note]
This command will be controlled as protection
facility. Non-permitted volume is shown without
LDEV# information(LDEV# information is " - "). This
command will be rejected with EX_ERPERM by
connectivity checking between Raid Manager and
Array.
–v errcnt
Displays statistical information for errors counted on
the target volumes. The error count is cleared when the
individual flag for integrity checking is disabled.
CFEC
: Block size validation error count.
MNEC
: Block header validation error count.
SCEC
: Data block checksum validation error count.
BNEC
: Block number validation error count.
Error codes
This command is rejected with EX_ERPERM by connectivity checking
between RAID Manager and the disk array.