HP XP RAID Manager Software User Manual
Page 161
161
raw device. If a volume is found, the command is
executed on the paired volume (–d) or group (–dg).
This option is effective without specification of the
–g group
option.
If the volume is contained in two groups, the command
is executed on the first volume encountered. If MU# is
not specified, it defaults to 0.
–d
[g] seq# LDEV# [ MU# ]
Searches the RM instance configuration file (local
instance) for a volume that matches the specified
sequence # and LDEV. If a volume is found, the
command is executed on the paired logical volume
(–d) or group (–dg).
This option is effective without specification of the
–g group
option.
If the volume is contained in two groups, the command
is executed on the first volume encountered only.
–FCA
[MU#]
Used to forcibly specify, for event waiting, a CA
P-VOL that is also a BC P-VOL. If the –l option is
specified, then the status of a cascading CA volume on
a local host (near site) is tested. If no –l option is
specified, then this option tests the status of a cascading
CA volume on a remote host (far site).
The target CA volume must be SMPL or P-VOL.
The MU# specifies the cascading mirror descriptor for
CA-Journal.
–FBC
[MU#]
Used to forcibly specify, for event waiting, a CA
P-VOL that is also a BC P-VOL. If the –l option is
specified, then this option tests the status of a cascading
BC volume on a local host (near site). If no
–l
option is specified, then this option tests the status of
a cascading BC volume on a remote host (far site).