beautypg.com

HP XP RAID Manager Software User Manual

Page 200

background image

200

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

PFUS

Since the PFUS state is referring to a Suspend state
with the Side File Full, the PFUS state is displayed as
PSUS by all commands except pairvolchk and the –fc
option of the pairdisplay command.

SVOL_PSUS

Displayed as SSUS by the pairdisplay command.

Error Codes

The table lists specific error codes for the pairvolchk command.

Examples

CA Async:

# pairvolchk -g oradb

pairvolchk:Volstat is P-VOL.[status=PAIR fence=ASYNC CTGID=2 MINAP=2

CA Sync:

# pairvolchk -g oradb

pairvolchk : Volstat is P-VOL.[status = PAIR fence = DATA MINAP = 2

LDEV =BLOCKED]

“MINAP” shows the minimum active paths to a specified group on the
P-VOL. If the array firmware does not support tracking the number of
active paths, then "MINAP" will not be displayed (as below).

“LDEV = BLOCKED indicates failure to link to an E-LUN by CA

BC:

# pairvolchk -g oradb

pairvolchk : Volstat is P-VOL.[status = PAIR ]

BC with CT Group:

# pairvolchk -g oradb

pairvolchk : Volstat is P-VOL.[status = PAIR CTGID = 1 ]

Category

Error Code

Error Message

Value

Volume status
unrecoverable

EX_ENQVOL

Unmatched volume status within the group

236

EX_EVOLCE

Pair volume combination error

235