beautypg.com

HP XP RAID Manager Software User Manual

Page 394

background image

394

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

HORCM_INST

#dev_group ip_address service

VG01 HOSTA horcm0

The UDP port name for HORCM communication in
"SYS$SYSROOT:[000000.TCPIP$ETC]SERVICES.DAT"

is defined

as shown in the example below.

horcm0 30001/udp

horcm1 30002/udp

Starting “horcm 0” and “horcm 1” as detached processes

$ run /DETACHED SYS$SYSTEM:LOGINOUT.EXE

/PROCESS_NAME=horcm0 -

_$ /INPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]

loginhorcm0.com

-

_$ /OUTPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run0.out -

_$ /ERROR=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run0.err

%RUN-S-PROC_ID, identification of created process is
00004160

$

$

$ run /DETACHED SYS$SYSTEM:LOGINOUT.EXE

/PROCESS_NAME=horcm1 -

_$ /INPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]

loginhorcm1.com

-

_$ /OUTPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run1.out -

_$ /ERROR=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run1.err

%RUN-S-PROC_ID, identification of created process is
00004166

You will be able to verify that HORCM daemon is running as a detached
process by using the SHOW PROCESS command.

#dev_group

dev_name

port#

TargetID

LU#

MU#

VG01

oradb1

CL1-H

0

3

0

VG01

oradb2

CL1-H

0

5

0

VG01

oradb3

CL1-H

0

7

0