beautypg.com

HP XP RAID Manager Software User Manual

Page 178

background image

178

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

MPE/iX

Before you execute this command, the non-written data that remains in the
buffer of the host must be given a flush for synchronization. For MPE/iX
systems this is VSCOSE of the volume set.

CA Operation

The following figure shows the usage of the –FCA option. In the example,
the command splits (to PSUS) the CA pair by specifying the name of the
BC group to which it is cascaded.

BC Operation

The following figure shows the usage of the –FBC option. In the example,
the command splits (to PSUS) a BC pair (MU#1) by specifying the MU#
and the name of the CA group to which it is cascaded.

SVOL

P/P

VOL

SVOL

SVOL

Ora(CA)

Oradb1(BC)

Oradb2(BC
)

0

1

0

Seq#30052

Seq#30053

BC environment

pairsplit -g oradb1 -rw -FCA

PVOL

S/P

VOL

SVOL

SVOL

Ora(CA)

Oradb1(BC)

Oradb2(BC
)

0

1

0

Seq#30052

Seq#30053

CA environment

pairsplit -g ora -FBC 1