HP XP RAID Manager Software User Manual
Page 210

210
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
If a device name is different in the DEVICE_FILE and
Device_File fields, then an LDEV is being referenced
by multiple device files. See the Examples section for
an example of such a case.
–h
Displays Help/Usage and version information.
–l lun
Specifies a LUN for a specified SCSI/Fibre Channel
target. Specifying a LUN without designating the target
ID is not allowed.
If this option is not specified, the command applies to
all LUNs.
If this option is specified, the –t option must also be
used.
–m
MU#
Displays the cascading mirror descriptor. If you specify
the –CLI option, raidscan will not display the
cascading mirror (MU1-4).
-m all
will display all cascading mirror descriptors.
–p port
[hgrp]
Specifies the name of a port to be scanned by selecting
it from CL1-A to CL1-R (excluding CL1-I and CL1-O),
or CL2-A to CL2-R (excluding CL2-I and CL2-O).
For the XP1024, the expanded ports CL3-A up to
CL3-R, or CL4-A up to CL4-R can also be selected.
For the XP12000, the expanded ports CL3-A up to
CL3-R, or CLG-A up to CLG-R can also be selected.
Port specifications are not case sensitive (CL1-A=
cl1-a= CL1-a= cl1-A).
This option must always be specified.
The [hgrp] option displays only the LDEVs mapped to
a host group on a XP1024/XP12000 port.
–pd raw_device
(UNIX only)
Specifies a raw_device name.