HP XP RAID Manager Software User Manual
Page 150
![background image](/manuals/398055/150/background.png)
150
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
matches the specified raw_device. If a volume is found,
the command is executed on the paired volume (–d) or
group (–dg). If the volume is contained in two groups,
this command executes for the first volume
encountered only. If MU# is not specified, it defaults to
0.
–d[g] seq# LDEV#
[ MU# ]
Searches the RM instance configuration file (local
instance) for a volume that matches the specified
sequence number (seq#) and LDEV. If a volume is
found, a command is executed on the paired logical
volume (–d) or group (–dg). If the volume is contained
in two groups, this command executes for the first
volume encountered only. If MU# is not specified, it
defaults to 0.
–f
[x|c|d|m|e]
–fx
displays the LDEV number in hexadecimal.
–fc
displays the copy operation rate and a completion
percentage. Detects and displays the status (PFUL,
PFUS) and confirms SSWS state as an indication of
SVOL_SSUS-takeover
. This option is also used to
display the copy operation progress, the Side File
percentage or the BITMAP percentage for
asynchronous pair volumes.
–fd
displays the relationship between the Device_File
and the paired volumes, based on the group (as defined
in the local instance configuration definition file). If
Device_File column shows unknown to either the local
or the remote host (instance), then it shows a volume
that is not recognized on the current host, and pair
operations are rejected (except the local option –l in
protection mode).
–fm
displays the Bitmap mode.
-fe displays the serial number and LDEV number of the
external LUNs mapped to the LDEV and additional