HP XP RAID Manager Software User Manual
Page 182
![background image](/manuals/398055/182/background.png)
182
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
the host possessing the primary volume goes down
because of a failure or the like.
–R[S]
(CA only) Bring the secondary volume forcibly into
SMPL mode.
–R[B]
(CA only) Used to bring the secondary volume forcibly
from SMPL to PSUE mode.
–r
[w]
(CA only) Used to specify a mode of access to the
secondary volume after paired volumes are split.
The –r option allows read-only access of the secondary
volume, –r is a default option.
The –rw option enables reading and writing from and
to the secondary volume.
–S
(Optional) Used to bring the primary and secondary
volumes into SMPL mode in which pairing is not
maintained. Data consistency is only maintained if
devices are in a suspend status (PSUS). If devices are in
a pair status (PAIR), data on the secondary volume will
not be consistent and not usable.
Returned Values
This command sets either of the following returned values in exit(), which
allows you to check the execution results.
The command returns 0 upon normal termination.
A nonzero return indicates abnormal termination. For the error cause and
details, see the execution logs.
Error Codes
The table below lists specific error codes for the pairsplit command.