beautypg.com

HP XP RAID Manager Software User Manual

Page 119

background image

RAID Manager command reference

119

The target volume of a local host must be a P-VOL.

This argument must be specified at the beginning of the
command arguments.

–t timeout

(Asynchronous paired volumes only)

Specifies the

maximum time in seconds to wait for a
resynchronization of P-VOL to S-VOL delta data. If the
timeout occurs, EX_EWSTOT is returned. This option
is required for an asynchronous paired volume; it has
no effect for a synchronous paired volumes.

–z

Makes this command enter interactive mode.

–zx

(Not for use with MPE/iX or OpenVMS)

Prevents using

RM in interactive mode.

Returned Values

The horctakeover command returns one of the following values in exit().

Normal termination

0: nop-takeover (no operation)

1: swap-takeover was successfully executed

2: SVOL-takeover was successfully executed

3: PVOL-SMPL-takeover was successfully executed

4: PVOL-PSUE-takeover was successfully executed

5: SVOL-SSUS-takeover was successfully executed

(This returned value depends on the microcode level.)

Abnormal termination

Other than the above. For the error cause and details, see the execution
logs.

Execution Log File

After the SVOL-takeover is executed, if inconsistent volumes exist, they
are displayed in the execution log file.