HP XP RAID Manager Software User Manual
Page 152
152
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
E-Seq#
: The production (serial) number of the external
LUN, “-” represents an unknown number.
E-LDEV#
: The LDEV# of the external LUN. “-”
represents an unknown number.
–FBC
[MU#]
Specifies a cascading BC volume in a combination BC
and CA environment. If the –l option is specified, this
option displays a cascading BC volume on a local host
(near site). If no –l option is specified, then this option
displays a cascading BC volume on a remote host (far
site).
The –m mode option cannot be specified.
–FCA
[MU#]
Displays a cascading CA volume in a combination CA
and BC environment. If the –l option is specified, this
option displays a cascading CA volume on a local host
(near site). If no –l option is specified, then this option
displays a cascading CA volume on a remote host (far
site).
The MU# specifies the cascading mirror descriptor for
CA-Journal.
–g group
Specifies a group name in the RM instance
configuration file. Group names are defined in the
HORCM_DEV
section of the RM instance
configuration file.
The command executes for the entire group unless the
–d pair_vol
argument is specified.
–h
Displays Help/Usage, and version information.
–l
Displays the paired volume status of the local host
(which issues this command).
–m mode
Displays the status of mirror descriptors for specified
pair logical volumes and volume pair status. The
cascading volume mode option can be designated as cas
or all.