beautypg.com

HP XP RAID Manager Software User Manual

Page 259

background image

259

Capacity(MB)

: Displays the total capacity in the

SnapShot pool.

Seq#

: Displays the serial number of the RAID.

Num

: Displays the number of LDEVs configured for

the SnapShot pool.

LDEV#

: Displays the number of the first LDEV

configured for the SnapShot pool.

–v errcnt

Displays the statistical information about errors on the
target volumes. Statistical information is cleared when
the individual flag for integrity checking is disabled.

Example

# raidvchkscan -p CL1-A -v errcnt

PORT# /ALPA/C TID# LU# Seq# Num LDEV# CFEC MNEC SCEC BNEC

CL1-A / ef/ 0 0 0 2332 1 0 0 0 0 0

CL1-A / ef/ 0 0 1 2332 1 1 0 0 0 0

CL1-A / ef/ 0 0 2 2332 1 2 0 0 0 0

CL1-A / ef/ 0 0 3 2332 1 3 0 0 0 0

CL1-A / ef/ 0 0 4 2332 1 4 0 0 0 0

CFEC

displays the block size validation error count.

MNEC

displays the block header validation error

count.

SCEC

displays the block checksum validation error

count.

BNEC

displays the block number validation error

count.

–v gflag

Display the flags for block data validation for target
volumes.

Example