HP XP RAID Manager Software User Manual

Page 143

background image

143

cc (BC only)

Used to specify the Cruising Copy mode

for volume migration. This option cannot be used with
the -split argument. This option is ignored if -c
is used.

–nocopy

(CA only)

Creates paired volumes without copying

data. The data consistency of SMPL volumes is assured
by the user.

–pid

(SnapShot only)

Identify the SnapShot pool with a pool

ID. LDEV’s in a group that has a PID belong to the
specified SnapShot pool. If a specific PID is not given,
the LDEVs will be designated with the default pool ID
(0).

–q

Terminates interactive mode and exits this command.

–split

(BC/SnapShot only) Splits the paired volume after
completing the pairing process.

-split

works differently based on the microcode

version:

XP256 microcode 52-46-xx or over

XP512 microcode 01-10-00/xx or over

XP1024/XP128

XP10000

XP12000

This option will return immediately with the
PVOL_PSUS and SVOL_COPY state changes. The
SVOL state will be changed to SVOL_SSUS after all
data is copied.

XP256 microcode 52-46-yy or under

XP512 microcode 01-10-00/xx or under:

After the command is executed, the volume status will
be PVOL_COPY and SVOL_COPY. The PVOL and
SVOL states will be changed to PVOL_PSUS and
SVOL_SSUS after all data is copied.