HP XP RAID Manager Software User Manual
Page 279

Troubleshooting RAID Manager
279
EX_ENPERM
A device mentioned in the
configuration file does not have
permission for a pair operation.
Use the pairdisplay or raidscan –find
verify
command to confirm that a pair
operation is permitted for the device.
EX_ENQCTG
The CT group in a group does not
match the CTGID number.
Confirm the CTGID by using the
pairvolchk
command.
EX_ENQSER
The group that was designated by
paircreate
(for BC) does not have the
same disk array unit, or the unitID is
not identical to the unitID of the same
serial# of the disk array.
Confirm the serial# by using the
pairdisplay
or the raidqry –r command.
EX_ENQSIZ
Unmatched pairing volume size.
Use the raidscan -f command to confirm
the volume size or number of the LUSE
volume, and change the SIZE of the
volumes to match.
EX_ENQVOL
The attributes or the fence level of the
primary and secondary volumes do not
match.
Confirm the attributes and fence level
settings using the pairdisplay command
and reset the volume attributes and fence
levels.
EX_ENXCTG
An available CT group for an Open
Systems volume does not exist for
asynchronous CA or BC.
Confirm whether all CT groups are
already used by other volumes.
EX_EPRORT
Mode changes denied due to retention
time
Verify the retention time for a target
volume using the raidvchkscan -v gflag
command.
EX_ERANGE
The argument or the result of the
argument exceeds the maximum
command value.
Re-issue the command, making sure to
correctly define all of the command
arguments.
EX_ERPERM
RAID permission denied.
Use the inqraid -CLI and raidqry -h
commands to confirm the type of RAID
permitted for RM.
(continued)
Command Error Problem
Action