HP XP RAID Manager Software User Manual
Page 160

160
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
BC Operation
The figure below shows the usage of the –FBC option. In the example, the
command tests the status of the intermediate S-VOL/P-VOL (MU#1)
through a specified pair group in a CA environment.
Syntax
pairevtwait –h
pairevtwait
{ –nomsg | –d pair_vol | –d[g] raw_device [ MU# ]
| –d[g]
seq# LDEV#
[ MU# ] | –FCA [ MU# ] | -FBC [ MU# ] | –g group | –h | –l
|–nowait |
–q | –s status . . .| –t timeout [ interval ] | –z[x] }
Arguments
–nomsg
Used to suppress messages when this command is
executed from a user program.
This option must be specified at the beginning of the
command arguments.
–d pair_vol
Specifies a paired volume name written in the
configuration definition file. The command executes
only for the specified paired volume.
–d
[g] raw_device [ MU# ]
(HP-UX, Linux, Solaris, Windows NT/2000/2003, AIX,
and MPE/iX only)
Searches the RM configuration file
(local instance) for a volume that matches the specified
PVOL
S/P
VOL
SVOL
SVOL
Ora(CA)
Oradb1(BC)
Oradb2(BC)
0
1
0
Seq#30052
Seq#30053
CA environment
pairevtwait -g ora -s psus -t 10 -FBC 1
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)