Section 7 Integration value measurement
Section
7
The range is automatically assigned depending on the measured value.
The decimal point and unit are changed automatically.
Unit: Wh/ VAh
0.00 ~
9999.99
10000.0 ~
99999.9
100000 ~
999999
1000.00 k
~
9999.99 k
10000.0 k
~
99999.9 k
100000 k
~
999999 k
1000.00 M
~
9999.99 M
10000.0 M
~
99999.9 M
100000 M
~
999999 M
1000.00 G
~
9999.99 G
10000.0 G
~
99999.9 G
100000 G
~
999999 G
When the value exceeds 999999G,
segment becomes “ “.
However the saved data is not lost.
* Elapsed time TIME
Displayed time changes with time as follows.
Elapsed time
00:00:00
~
99:59:59
hour: minute: second
100:00
~
9999:59
hour: minute
10000
~
999999
hour
Ɣ Over-range indication/ others
* When the input voltage and the current exceeds the max display counts,
or mark is displayed on the LCD. In this case, accurate
measurement cannot be made.
* On the
W
range, when the P (active power) is shown by bars “- - - -”,
this means that the increment in electrical energy is insignificant.
Refer to “6-5-2 Over-range indication/ Bar indication” in this manual.