Ɣ Time (clock)
This instrument has clock function, and the time is set to Japan time by
default. On
SET UP
range, time/date information can be viewed or
changed. Refer to “Setting 07” in section 4 in this manual.
Ɣ Backlight
Pressing the
BACKLIGHT
key ( ) switches on/off the backlight for LCD.
The backlight is automatically switched off when it remains on for about 5min.
Ɣ Data hold
The indicated value on the LCD is held by pressing the
DATAHOLD
key
( ), and “ ” mark appears on the LCD.
At this bout, the instrument is performing calculation and data save.
Data hold function works on each range as follows.
“Available” : Pressing the
DATAHOLD
key holds the indicated value.
The values on each measurement are also held.
“Invalid”
: Data hold function doesn’t operate even if the
DATAHOLD
key is
pressed.
Data hold function on each range
Status
W
range
Wh
range
DEMAND
range
SET UP
range
Measuring
instantaneous value
Available
Invalid
Stand-by for integration
Invalid
Measuring
integration value
Available
Invalid
Stand-by for demand
Invalid
Measuring
demand value
Available Invalid
Data hold function is released and “ ” mark disappears by pressing the
DATAHOLD
key again. This function can be released on any range.
NOTE
* Keys are locked by pressing the
DATAHOLD
key at least 2 sec. either Data
hold function is on or off. If both Data hold and Key lock functions are
enabled at the same time, Data hold function cannot be released until the
Key lock function is released.
* When the Function switch is set to OFF, both functions are released.