beautypg.com

6 .4 flow rates and totals, 6 .4 .1 flow rate limits & scaling – KROHNE Summit 8800 Vol 2 User Manual

Page 92

background image

92

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol2 R02 en

SUMMIT 8800

STREAM CONFIGURATION

06

Beta

The compressibility factor can be selected from the API 11.2.1M or 11.2.2M

standard.

CTLm

Correction for temperature for the liquid at the meter. For selections, see below.

CPLm

Correction for pressure for the liquid at the meter. For selections, see below.

CTLs

Calculation of the liquid temperature at the density measurement point (CTLρ).

For selections, see below.

CPLs

Calculation of the liquid pressure at the density measurement point (CTPρ). For

selections, see below.

Correction factors for temperature may be selected from the following standards (Eqn CTLm

and CTLs):

Keypad
ASTM D1250 IP200 Table 54

Eqn 72 and 34

API Chp 12.2.5.3 Table 54A

Eqn 70 and 32

GPA TP-25

Eqn 80 and 40

GPA TP-27 API Ch11.2.4 Table 23E/24E Tb 60°F See Standard
GPA TP-27 API Ch11.2.4 Table 53E/54E Tb 15°C See Standard
GPA TP-27 API Ch11.2.4 Table 59E/60E Tb 20°C See Standard

Correction factors for pressure may be selected from the following standards (Eqn CPLm and

CPLs):

Keypad
API Chp 12.2.5.3 Table 54A

Eqn 71 and 33

6 .4 Flow rates and totals

Liquid

Gas

Steam

This chapter describes the parameters related to flow rate:

• Its range and alarm limits

• Its display and print scaling factors

• The meter correction factors

As there are differences between oil, gas and steam corrections, we created two separate para-

graphs for this.

6 .4 .1 Flow rate limits & scaling