beautypg.com

9 .1 station totals – KROHNE Summit 8800 Vol 2 User Manual

Page 132

background image

132

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol2 R02 en

SUMMIT 8800

STATION

09

9. Station

A metering station may consist of multiple incoming streams from suppliers and multiple out-

going streams to customers. In this case it is is beneficial to be able to combine the flows from

the different supplier or customers to one total.

For this purpose, in the SUMMIT two stations (station A and B) can be defined each with up to

5 streams. Each stream can be added to or subtracted from the station total. A recalculation to

the station pressure and temperature will be done.

9 .1 Station totals

Liquid

Gas

Steam

Figure 136 Define station totals

For each station (A and/or B), define which of the 5 streams have to be summed or subtracted to

get a station total.

For example, selecting

• SA stream 1 sum,

• SA stream 2 sum

• SA stream 4 sum

• SA stream 5 subtract

translates as

Station total = stream 1 + stream 2 + stream 4 – stream 5.

For both the metric and US customary units, for each of type of total a scaling factor for display

of the totals can be given, similar to the stream totals. This multiplier will normally be 1, 1000 or

1000000.