10 .1 .6 valve control – KROHNE Summit 8800 Vol 2 User Manual
Page 146
146
www.krohne.com
08/2013 - MA SUMMIT 8800 Vol2 R02 en
SUMMIT 8800
PROVER
10
CTSp select
Correction factor according to selectable API standard or keypad value
CTSp keypad
User defined keypad value
CTSp precision
Selectable precision – rounded, full, truncated
CTSp dps
Precision decimal place for reporting
CTSp t
Prover reference temperature
CTSp expansion
Prover cubical expansion coefficient
CTSp detector
Detector linear expansion
CPSp select
Correction factor according to selectable API standard or keypad value
CPSp keypad
User defined keypad value
CPSp precision
Selectable precision – rounded, full, truncated
CPSp dps
Precision decimal place for reporting
CPSp p
Prover reference pressure
CPSp D
Inner diameter of prover
CPSp t
Wall thickness of prover
CPSp E
Metal modulus of elasticity
10 .1 .6 Valve control
Liquid
Gas
Steam
Several valves can be controlled automatically during proving and can be selected from the 18
valves. They work in conjuction with the prover valves as defined under run switching.
Depending on the prover type selected the following valves can be controlled:
Figure 153 Prover valve control, bi-directional
Figure 154 Prover valve control, uni-directional or small volume