beautypg.com

10 .1 .6 valve control – KROHNE Summit 8800 Vol 2 User Manual

Page 146

background image

146

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol2 R02 en

SUMMIT 8800

PROVER

10

CTSp select

Correction factor according to selectable API standard or keypad value

CTSp keypad

User defined keypad value

CTSp precision

Selectable precision – rounded, full, truncated

CTSp dps

Precision decimal place for reporting

CTSp t

Prover reference temperature

CTSp expansion

Prover cubical expansion coefficient

CTSp detector

Detector linear expansion

CPSp select

Correction factor according to selectable API standard or keypad value

CPSp keypad

User defined keypad value

CPSp precision

Selectable precision – rounded, full, truncated

CPSp dps

Precision decimal place for reporting

CPSp p

Prover reference pressure

CPSp D

Inner diameter of prover

CPSp t

Wall thickness of prover

CPSp E

Metal modulus of elasticity

10 .1 .6 Valve control

Liquid

Gas

Steam

Several valves can be controlled automatically during proving and can be selected from the 18

valves. They work in conjuction with the prover valves as defined under run switching.

Depending on the prover type selected the following valves can be controlled:

Figure 153 Prover valve control, bi-directional

Figure 154 Prover valve control, uni-directional or small volume