STREAM CONFIGURATION

06

6 .2 .1 .1 Meter Input API 5 .5 Level B to E

Figure 65 Define pulse based meter input API level B to E

Turbine type

API 5.5 Level B to E.

Turbine frequency

offset

An offset to be added to the input frequency. Ideal for testing purpose: even when

no input is available, a frequency can be set to simulate an input. Make sure that

in normal mode the offset is 0.

K Factor

The total number of pulses corresponding to one unit of flow is the K-factor. A

separate scaling K factor can be entered for both HF and LF inputs in pulses per

volume.

Turbine minimum

frequency

Low cut-off frequency. This is frequency below which the flow will be considered 0.

Blade ratio

Ratio between the two frequency inputs. For one input set to 0. For two identical

frequency inputs set to 1

6 .2 .1 .2 Meter Input API 5 .5 Level A

Figure 66 Figure 65 define pulse based meter input API level A