beautypg.com

KROHNE Summit 8800 Vol 2 User Manual

Page 113

background image

113

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol2 R02 en

SUMMIT 8800

STREAM CONFIGURATION

06

6 .10 .3 Base sediment and water

Liquid

Gas

Steam

When crude oil is extracted from an oil reservoir or well, it contains certain impurities such as

water, and suspended solids. Sediment or mud is referred to the solid matter and water is the

result of the oil field itself, and from water injection used to extract the oil from the ground.

This section defines the selection process to arrive to an “in use” value for BS&W. There are

3 selections in order of priority with each 4 choices. The SUMMIT will start to check the first

selection. If the value is valid (not in alarm) then this selection will be chosen. If not, then the

second selection will be checked etc.

This following page sets the options and parameters for the calculations used for the base sedi-

ment and water correction in accordance with API Ch 12.2.1:

Figure 112 Basic sediment & water

The BS&W value can be sourced from:

None

No functionality or transmitter selected, the option will be skipped.

Keypad

The user defined value for this range will be chosen

Sensor

The transmitters value as defined in hardwaret, will be used.

Serial

Value as sent by Modbus e.g. from a PLC, or smart transmitter will be used.

Other parameters also include the minimum and maximum alarm limits, the high and low

warning limits, as well as the fixed user defined keypad value.