6 .10 .3 Base sediment and water
Liquid
Gas
Steam
When crude oil is extracted from an oil reservoir or well, it contains certain impurities such as
water, and suspended solids. Sediment or mud is referred to the solid matter and water is the
result of the oil field itself, and from water injection used to extract the oil from the ground.
This section defines the selection process to arrive to an “in use” value for BS&W. There are
3 selections in order of priority with each 4 choices. The SUMMIT will start to check the first
selection. If the value is valid (not in alarm) then this selection will be chosen. If not, then the
second selection will be checked etc.
This following page sets the options and parameters for the calculations used for the base sedi-
ment and water correction in accordance with API Ch 12.2.1:
Figure 112 Basic sediment & water
The BS&W value can be sourced from:
None
No functionality or transmitter selected, the option will be skipped.
Keypad
The user defined value for this range will be chosen
Sensor
The transmitters value as defined in hardwaret, will be used.
Serial
Value as sent by Modbus e.g. from a PLC, or smart transmitter will be used.
Other parameters also include the minimum and maximum alarm limits, the high and low