SUMMIT 8800
PROVER
10
Figure 143 Prover options: general, proving points
Settings
Depending on the prover type, additional settings are needed as follows:
Figure 144 Prover options: general settings, uni-directional prover
Ball release time
Release command time to valve
Maximum loop time
Allowable time for sphere to travel a complete loop – chamber to chamber
Maximum chamber time
Time for sphere to travel past last detector switch to home chamber
Pump check delay time
Pump running signal check status wait delay
Figure 145 Prover options: general settings, bi-directional prover
Maximum loop time
Allowable time for sphere to travel a complete loop – chamber to chamber
Maximum chamber time
Time for sphere to travel past last detector switch to home chamber
Figure 146 Prover options: general settings, small volume prover
Maximum forward time
Piston travel time from start to end position
Maximum reverse time
Piston start position recovery time
Home detection
The use of a home detector switch – yes or no
Plenum deviation limit
Maximum deviations between calculated and measure plenumm pressure
Plenum deviation time
Deviation time allowable for limit