SUMMIT 8800

PROVER

10

Plenum constant R

Defined value for plenum R constant

Plenum constant pressure Defined value for plenum pressure constant
Detector temperature

The use of detector to measure temperature – yes or no

Figure 147 Prover options: general settings, master meter

Proving length section

Proving cycle - start to end based on time or number of pulses

Length of Proving run

Defined limit of pulses or time required for proving length

Meter correction

Correction data for the master meter – MF or K-factor

Meter preset KF

Master meter K-factor value

10 .1 .4 .2 Stability

The prover can be configured to check the stability of volume, pressure and temperature before

the proving sequence is initiated.

Once the proving sequence has been initiated, the prover will wait for the specified minimum

stability duration time (in seconds) before adjusting the prover loop outlet valve, it will then wait

up until a user selectable maximum stability duration time (in seconds) for the flow, pressure

or temperature to stabilise. If the required stabilisation level is not met then the prove will be

aborted.

The parameters for each of the volume, pressure and temperature are: