SUMMIT 8800

HARDWARE DETAILS

05

5 .2 .4 Density Transducer

A densitometer or density transducer is used to measure the density of the medium during

flowing conditions. Reference source not found. for details. The density is used in calculations

and corrected for temperature and/or pressure as required in many standards.

The type of density transducer and its selection within the stream measurement is made in the

hardware section.

Densitometers can be connected to the SUMMIT 8800 via:

• Digital (Frequency)

• HART

• Analog (4-20mA)

• Serial (modbus)

In most of the cases a densitometer will be used. The SUMMIT supports models from Emerson/

Solartron 781x and Sarasota ID900 which have a frequency output. Up of two densitometers may

be used per stream.

Figure 55 Densitometer input selection

Also a Hart or analog input may be used. In this case only one sensor can be used.

Figure 56 Density input selection