SUMMIT 8800

HARDWARE DETAILS

05

Figure 51 Temperature serial input selection

In certain meters, such as in the Coriolis meter, there is also the meter temperature. If this is

included in the modbus master protocol of that meter, the same variable as for modbus slave is

used. So although this is a fixed protocol which cannot be changed, the serial temperature can

then still be used.

5 .2 .3 Pressure Transmitter

An important measurement for a flow computer is the pressure, specifically for gas. This can be

used for the correction (compensation) of flow, as well as density correction which is required

according to certain standards.

The SUMMIT can handle 1 to 3 transmitters per stream:

Figure 52 Stream and station pressure selection in Hardware input