SUMMIT 8800

STREAM CONFIGURATION

06

Meter input

the meter connected and its basic settings

Pulse input

the preference for serial or pulse input and the pulse input setting if used

Meter correction

the correction for expansion of the meter body for pressure and

temperature

Meter information

the identification of the meter

Most smart UFM have the option to send the flow data via a serial link and via pulses. In case

pulses are used, then the API level has to be selected. For liquid the pulse input can either be

API 5.5 level A or level B to E, for gas and steam API 5.5 Level B to E only.

API 5.5 Level B to E

for single or dual pulse with the same of different frequencies and pulse

monitoring.

API 5.5 Level A

for dual pulse with pulse correction.

See also chapter 3.1.

6 .2 .2 .1 Meter input

Define which meter type or manufacturer are applicable along with the associated parameters

associated with the meter.

Figure 68 Example ultrasonic meter input section