SUMMIT 8800

HARDWARE DETAILS

05

• Coriolis meters.

In most cases they will be connected as API level B-E, thus pulse 1 as the meter frequency and

possibly pulse 2 as a monitor frequency. See below for e.g. meter 1: turbine, meter 2: ultrasonic

and meter 4: Coriolis.

Figure 38 Setup of a meter pulse in Hardware selection

With digital input 2 of board 2, slot 3 used as the monitor frequency input for a turbine:

Figure 39 Setup of a monitor pulse in Hardware selection

Alternatively, a dual pulse might be connected as an API level A input. Select API 5.5 Level A for

input 1. Input 2 will automatically be used, since they are hardware coupled for this function.

Figure 40 Setup of a Level A dual pulse in Hardware selection