STREAM CONFIGURATION

06

Isentropic Exponent

Isentropic exponent of the fluid at flowing .Options available for source
Keypad

Fixed user defined value

Method 1

From calculated Ratio specific heat γ0

AGA 10

Natural gas detailed density analysis based on speed of sound

6 .2 .3 .1 .1 Orifice Plate

The following parameters are available for this selection

Equation

Orifice equation used for flow calculation
Keypad

User defined fixed value for coefficient of discharge

ISO 5167

As per standards for 1991, 1997, and 2003 with the change of temperature to be

used.

AGA3

Calculated independently from the type of fluid with a deadweight correction factor

Tappings

Pressure taps for the orifice installed based on location where the reading is taken.
Flange

Placed both sides of the orifice close to the face plate, usual an inch either side.

Corner

Pressure taps on both sides of the flange holding the orifice plate

D & D/2

Located in the pipe wall upstream and downstream of the face plate at half length.

Joule Thompson

A pressure drop and temperature change based on a regulating process in conjunction with a steady

flow across a restricted section.
Keypad

A user defined fixed value for the Joule Thomson process

Reader-Harris

Simplified version of the Joule Thompson equation

ISO 5167:2003

Calculations to ISO 5167, based on temperature method.

6 .2 .3 .1 .2 Classical venturi

When selecting classical venturi as the measurement source the following parameters will need

populating.

Pressure loss

Pressure taps for the orifice installed based on location where the reading is taken.
Calculated

……..

Keypad

User defined fixed value

Coefficient of discharge

A selection based on the tube installation, or defined values, as set by ISO5167 for the convergent section

of the venturi.
As cast
Machined
Rough weld
CoD table

see paragraph 6.2.3.3

Keypad
Constants

An alternative method to calculating the loss of pressure as defined the Beta

calculation.

6 .2 .3 .1 .3 Venturi nozzle